| SUGGESTED INSTRUMENTS ANGLE |
|
SEGGESTED
INSTALLATION ANGLE 0° - 45° / MAXIMUM ALLOWED 80° |
FUNCTIONING
INFO:
- EVERY TYPE OF GAUGE (FUEL LEVEL, TERMOMETER, PRESSARE,…) CAN BE DRIVER, UPON
REQUEST, BY MOST OF THE SENDERS AVAILABLE ON THE MARKET.
- EVERY TYPE OF TACHOMETER CAN BE DRIVER, UPON REQUEST, BY STANDARD SIGNALS (ALTERNATOR
W, HALL EFFECT SENDERS,…) OR CUSTUMER DEFINED ONES.
- EVERY TYPE OF SPEEDOMETER CAN BE DRIVER, UPON REQUEST, BY STANDARD SIGNALS
(HALL EFFECT SENDERS,…) OR CUSTUMER DEFINED ONES.
- ALL THE INSTRUMENTS ARE FRONT PROTECTED AGAINST WATER AND DUST (IP 66) IF NOT
DIFFERENTLY SPECIFIED.
- THE LIMIT WORKING TEMPERATURES ARE –30 ÷ +75°C FOR ALL THE INSTRUMENTS, IF
NOT DIFFERENTLY SPECIFIED.
- THE LIMIT STORAGE TEMPERATURES ARE –35 ÷ +85°C FOR ALL THE INSTRUMENTS, IF
NOT DIFFERENTLY SPECIFIED.
Gauge calibration table n°1
|
BAR |
OHM |
BAR |
OHM |
BAR |
OHM |
|
0 |
335÷285 |
0 |
335÷285 |
0 |
335÷285 |
|
4 |
135÷100 |
6 |
135÷100 |
12 |
135÷100 |
|
8 |
25÷0 |
12 |
25÷0 |
24 |
25÷0 |
|
LEVEL |
OHM |
°C |
OHM |
°C |
OHM |
|
0 |
335÷285 |
40 |
1650÷800 |
50 |
1080÷530 |
|
½ |
135÷100 |
80 |
287÷207 |
100 |
150÷113 |
|
4/4 |
25÷0 |
120 |
86÷66 |
150 |
40÷32 |
Gauge calibration table n°2
| BAR |
OHM |
BAR |
OHM |
BAR |
OHM |
| 0 |
10 |
0 |
10 |
0 |
10 |
| 2 |
82 |
4 |
88 |
10 |
92 |
| 5 |
184 |
10 |
184 |
25 |
184 |
| LEVEL |
OHM |
°C |
OHM |
°C |
OHM |
| 0 |
3 |
40 |
287,4 |
50 |
322,8 |
| ½ |
85 |
80 |
69,1 |
100 |
65,2 |
| 4/4 |
180 |
120 |
22,7 |
150 |
18,6 |